Fida 10/30CM 2*5KV Ignition Transformer
Technical specs, application notes, replacement checks, and related model references.
Product Overview
The FIDA 10/30CM 2*5KV is a high-performance ignition transformer engineered in Italy for industrial and commercial gas and oil burners. Utilizing advanced resin encapsulation technology, this transformer ensures reliable, high-voltage spark generation even under demanding operational conditions. It provides exceptional dielectric strength, thermal stability, and resistance to moisture and electromagnetic interference, ensuring consistent burner light-off while adhering to stringent European safety standards (EN 61558-2-3).
Technical Specifications
Component Type
Ignition Transformer
Secondary Voltage
2*5 kV
Secondary Current
30 mA
Output Type
Dual Pole (Oil / Gas)
Duty Cycle (ED)
33% ED (Standard) / 100% (Continuous)
Insulation Method
Resin Encapsulated / Potted
Approvals
CE, EN 61558-2-3
Selection Notes & Data Verification
The 10/30CM 2*5KV page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Knowledge
FAQ
What is Fida 10/30CM 2*5KV used for?
Fida 10/30CM 2*5KV is referenced as a ignition transformer for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can 10/30CM 2*5KV replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing 10/30CM 2*5KV?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if 10/30CM 2*5KV fits your combustion chamber and backpressure requirements.
Contact Engineering