ResideoFlame Detectors

Resideo IRD1020.1 1653204 White Enhanced Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Resideo IRD1020.1 1653204 White Enhanced is an industrial-grade flame detection sensor designed to interface seamlessly with primary burner control units. Utilizing advanced optical sensing technologies—such as cadmium sulfide (Cad Cell) for oil flames or infrared (IR) for gas/oil applications—it delivers instantaneous flame verification. Its authoritative sensitivity and robust housing prevent nuisance lockouts caused by refractory glare, ensuring optimal safety and efficiency in complex combustion systems.

Technical Specifications

Sensor Type

Infrared (IR) Flame Detector

Spectral Sensitivity

800 - 1000 nm

Viewing Angle

Axial or Radial

Protection Class

IP 54

Operating Temperature

-20°C to +60°C

Selection Notes & Data Verification

The IRD1020.1 1653204 White Enhanced page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Resideo IRD1020.1 1653204 White Enhanced used for?

Resideo IRD1020.1 1653204 White Enhanced is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can IRD1020.1 1653204 White Enhanced replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing IRD1020.1 1653204 White Enhanced?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if IRD1020.1 1653204 White Enhanced fits your combustion chamber and backpressure requirements.

Contact Engineering