LamtecFlame Detectors

Lamtec FFS07 Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The LAMTEC FFS07 is an advanced industrial flame scanner engineered for the reliable and fail-safe detection of combustion flames in high-demand environments. Utilizing state-of-the-art UV or IR sensing technologies, it accurately discriminates between the target flame and background radiation or adjacent burners. Compliant with SIL 3 / EN 298 standards, this detector seamlessly integrates with LAMTEC burner management systems (such as ETAMATIC and BT300) to ensure optimal combustion safety and continuous operational availability.

Technical Specifications

Sensor Technology

UV / IR (Model dependent)

Safety Integrity Level

SIL 3 (IEC 61508) Capable

Housing Material

Robust industrial casing

Compatibility

LAMTEC ETAMATIC, BT300, FMS

Approvals

CE (EN 298), UL, FM

Selection Notes & Data Verification

The FFS07 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Lamtec FFS07 used for?

Lamtec FFS07 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can FFS07 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing FFS07?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if FFS07 fits your combustion chamber and backpressure requirements.

Contact Engineering