Honeywell TMG740-3 MOD.43-35 110V Flame Detector
Technical specs, application notes, replacement checks, and related model references.
Product Overview
The Honeywell (Satronic) TMG740-3 MOD.43-35 110V is a specialized burner control box for forced draft gas and oil burners. Based on authoritative Satronic/Honeywell technical manuals, it provides highly stable ignition sequencing, flame monitoring, and safety lockout functions. Designed to handle both single and multi-stage burner operations, the TMG740-3 MOD.43-35 110V features precise timing circuits and robust interference immunity, making it a trusted component in European-style combustion systems. It is fully compliant with stringent European safety directives for thermal process equipment.
Key Features
- Component Type: Satronic Primary Burner Control Box
- Application: Forced draft gas, oil, or dual-fuel burners
- Safety Standard: Compliant with EN 298 / EN 230 directives
- Monitoring: Compatible with UV, IR, or ionization flame detectors
- Design: Plug-in base architecture for easy maintenance and replacement
Technical Specifications
Operating Voltage
AC 110-120V
Protection Class
IP40
Selection Notes & Data Verification
The TMG740-3 MOD.43-35 110V page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Models
Related Knowledge
FAQ
What is Honeywell TMG740-3 MOD.43-35 110V used for?
Honeywell TMG740-3 MOD.43-35 110V is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can TMG740-3 MOD.43-35 110V replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing TMG740-3 MOD.43-35 110V?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if TMG740-3 MOD.43-35 110V fits your combustion chamber and backpressure requirements.
Contact Engineering