EclipseServo Motors

Eclipse 10042656 Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Eclipse (Honeywell Thermal Solutions) 10042656 is an industrial-grade, heavy-duty servomotor engineered for the precise positioning of air and gas control valves in high-demand combustion systems. Designed to withstand harsh industrial environments, this actuator provides highly reliable, repeatable modulation and on/off control. By eliminating mechanical linkage slop and offering high-resolution positioning, it ensures optimal air-to-fuel ratio control, maximizing burner efficiency while minimizing NOx and CO emissions.

Technical Specifications

Component Type

Industrial Actuator / Servomotor

Application

Air and Gas Valve Modulation

Housing

Rugged industrial enclosure (NEMA/IP rated)

Control Interface

Analog (4-20mA / 0-10V) or Digital (Model specific)

Integration

Compatible with Eclipse / Honeywell Burner Management Systems

Approvals

CE, UL, CSA (Model dependent)

Selection Notes & Data Verification

The 10042656 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Eclipse 10042656 used for?

Eclipse 10042656 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can 10042656 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing 10042656?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if 10042656 fits your combustion chamber and backpressure requirements.

Contact Engineering