Dungs ZRDLE415/5 Flame Detector
Technical specs, application notes, replacement checks, and related model references.
Product Overview
The DUNGS ZRDLE415/5 is an authoritative Class A Single-stage Solenoid Valve designed for the safe shut-off and regulation of fuel gases in industrial burner applications. Manufactured to the highest German engineering standards, it provides rapid closing times (< 1s) and fail-safe operation to prevent unburned gas leakage. With its robust die-cast aluminum body and high flow capacity, the ZRDLE415/5 is a cornerstone of modern gas train architectures, ensuring strict compliance with EN 161 and international safety directives.
Technical Specifications
Valve Class
Class A, Group 2 (EN 161)
Max Operating Pressure
500 mbar (Typical)
Closing Time
< 1 second
Housing Material
Die-cast Aluminum
Protection Class
IP 54 (Standard) / IP 65 (Optional)
Opening Profile
Slow opening with adjustable fast stroke
Selection Notes & Data Verification
The ZRDLE415/5 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Models
Related Knowledge
FAQ
What is Dungs ZRDLE415/5 used for?
Dungs ZRDLE415/5 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can ZRDLE415/5 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing ZRDLE415/5?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if ZRDLE415/5 fits your combustion chamber and backpressure requirements.
Contact Engineering