DungsControllers

Dungs MPA4112/230 VAC Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The DUNGS MPA4112/230 VAC is an authoritative burner management and actuation component designed for the precise control of fuel and air flow in industrial thermal applications. Whether serving as a central microprocessor controller (MPA) or a high-torque servomotor/actuator (SAD/STA), it integrates flawlessly into complex combustion architectures. This component provides exceptional positioning accuracy, ensuring reliable ignition sequencing and optimized modulation.

Technical Specifications

Application

Burner Management / Air-Gas Modulation

Communication

CAN-Bus / Modbus / Analog (0-10V, 4-20mA)

Protection Class

IP 54 / IP 65

Quality Standard

ISO 9001, SIL capable (where applicable)

Manufacturer

Karl Dungs GmbH & Co. KG

Selection Notes & Data Verification

The MPA4112/230 VAC page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Dungs MPA4112/230 VAC used for?

Dungs MPA4112/230 VAC is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can MPA4112/230 VAC replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing MPA4112/230 VAC?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if MPA4112/230 VAC fits your combustion chamber and backpressure requirements.

Contact Engineering